This Blog is to share our knowledge and expertise on Linux System Administration and VMware Administration

Monday, November 27, 2017

Integrated Lights Out Manager ILOM Command line Linvirtshell

Integrated Lights Out Manager ILOM Command line

Login with ILOM root password
[root@testserver ~]# ssh test-ilom.example.com
Oracle(R) Integrated Lights Out Manager
Version 3.2.8.25 r114493
Copyright (c) 2016, Oracle and/or its affiliates. All rights reserved.
Warning: HTTPS certificate is set to factory default.
Hostname: test-ilom

Below targets are available to check in console. Once you run ls command, will get the property information of hardware. In that property we can get ILOM IP address, MAC ID, Server Model, Serial No & Operating system detail as well.

-> ls

 /System
    Targets:
        Open_Problems (0)
        Processors
        Memory
        Power
        Cooling
        Storage
        Networking
        PCI_Devices
        Firmware
        BIOS
        Log
    Properties:
        health = OK
        health_details = -
        open_problems_count = 0
        type = Rack Mount
        system_fw_version = 3.2.8.25
        locator_indicator = Off
        power_state = On
        actual_power_consumption = 305 watts
        action = (none)

a. To check power supply status
-> cd /System/power
/System/Power

-> show

 /System/Power
    Targets:
        Power_Supplies

    Properties:
        health = OK
        health_details = -
        actual_power_consumption = 383 watts
        max_permitted_power = 788 watts
        installed_power_supplies = 2
        max_power_supplies = 2

->
Login as root & run ipmitool command.
[root@test-ilom~]# ipmitool sunoem cli
Connected. Use ^D to exit.
-> show -l all /System/Power/Power_Supplies location health -t
Target             | Property              | Value
-------------------+-----------------------+-----------------------------------
/System/Power/     | health                | OK
Power_Supplies/   |                       |
Power_Supply_0   |                       |
/System/Power/     | location              | PS0 (Power Supply 0)
Power_Supplies/   |                       |
Power_Supply_0   |                       |
/System/Power/     | health                | OK
Power_Supplies/   |                       |
Power_Supply_1   |                       |
/System/Power/     | location              | PS1 (Power Supply 1)
Power_Supplies/   |                       |
Power_Supply_1   |                       

b. To check Processors status
-> cd Processors
/System/Processors

-> show

 /System/Processors
    Targets:
        CPUs

    Properties:
        health = OK
        health_details = -
        architecture = x86 64-bit
        summary_description = Two Intel Xeon Processor E5 Series
        installed_cpus = 2
        max_cpus = 2

c. To check BIOS version
-> cd BIOS
/System/BIOS

-> show

 /System/BIOS
    Targets:
        Config

    Properties:
        system_bios_version = 17120100
        boot_mode = Legacy
        reset_to_defaults = none

No comments: